Motor output 1A, 2A peak
Function outputs 2, ½A maximum total function output.
Supports extended addressing, addresses 1-9999 available.
Supports CV19 advanced consisting.
Supported CVs and default values/settings
CV
|
Definition
|
Default
|
1
|
Locomotive Address
|
3
|
2
|
Start Voltage
|
|
3
|
Acceleration
|
|
4
|
Deceleration
|
|
5
|
Maximum Voltage/Speed
|
|
6
|
Mid Voltage/Speed
|
|
7
|
Version
|
|
8
|
Manufacturer ID
|
|
17
|
Extended Address, High Byte
|
0
|
18
|
Extended Address, Low Byte
|
0
|
19
|
Consist Address
|
|
29
|
Decoder Configuration Byte 1
|
5
|
Decoder reset functions
Write 08 to CV 8 to reset att CV values
Write 09 to CV 8 to reset all values except speed tables.